Tactile sensing for surgery and grasping

Minimally invasive surgery leaves surgeons with a camera view and little sense of touch. The work adds force sensing and haptic feedback to graspers, a slip reflex to robot fingers and steering to capsule endoscopes.

75 mNforce difference detected with visual and haptic feedback
85 msrobot grip response to slip, comparable to humans
110°maximum bending of the tethered capsule
Haptic feedback

Finding the smallest grip force a hand can tell apart

Robotic surgery provides video but no sense of grip force. A sensorized grasper measured grip force and a fingertip indenter reproduced it. Across 60 participants, the smallest detectable difference was 100 mN by sight, 87.5 mN by touch and 75 mN with both.

sensorized grasper on tissuefingertip indenter0 mN25 mN50 mN75 mN100 mNVisual100Haptic87.5Both75
Feedback
75 mNsmallest force difference detected, with combined visual and haptic feedback
28.6%lower than with visual feedback alone, and 15.4% lower than with haptic feedback alone

Sixty participants compared pairs of grasps and reported which was firmer, until the difference could no longer be detected. Haptic feedback gave lower thresholds than visual feedback, and the combination gave the lowest. The combined threshold was within 13.1% of the prediction of a sensory integration model.

Sources: IEEE Robotics and Automation Letters, 2021, and the participant dataset. The grasper sensor is the subject of a US patent.

Slip detection

Giving robot fingers a slip reflex

When a held object begins to slide, the human grip tightens reflexively. A bio-inspired controller gives robot fingers a comparable reflex with an 85 ms response delay.

Slipped 1.93 mmload and maximum holding force (N)slip sensor spikes85 ms responseslip distance (mm)
Added load
Reflex
LoadHolding force

Mechanoreceptors in the skin fire when an object slides across it. The method emulates them: a slip sensor converts motion into spikes, and each spike increases the grip force. In laboratory trials, slip was arrested before the object fell in 80% of cases, with a response time under 85 ms, comparable to human grip adjustment.

Source: IEEE Sensors Journal, 2019. A 2017 paper tuned the same trade-off between slip and grip force with a monotonic PI controller. Only the 85 ms delay is published; the rest is illustrative.

Capsule endoscopy

Steering a swallowed camera with three tendons

A tethered capsule endoscope is swallowed like a pill and needs no anesthesia, but its cord cannot orient the camera. Three linear actuators pull tendons through a short bending section, giving 360° of direction and up to 110° of bending.

stomach phantomside view, in the plane of the bendtendon pullABCblack: shortened, grey: released
Dragging within the circle orients the capsule.ABC
60°bending angle (maximum 110°)
30°direction (0 to 360°)

Above 20° of bending, the 2015 prototype reached the target direction with a mean error within 1°.

Sources: IEEE CIS 2015 and URAI 2017. The workspace was measured with the capsule deployed 40 mm.

Other papers

Neuromorphic touch, sensor gloves and gas sensing

2013 · NUS

Spike-based tactile encoding

A fabric sensor array encoded contact as skin-like spike patterns, and a spike-timing classifier discriminated object curvatures with more than 99% accuracy.

IEEE Sensors

2013 · NUS

Object shape recognition with a sensor glove

Finger joint angles from a sensor glove identified boxes, cylinders and spheres with 100% accuracy, falling to 71% when each shape was grasped in more than one way.

IEEE ICCA

2016 · QU

Optical gas sensing for H. pylori

A dye-coated dual optical fiber detects ppm levels of carbon dioxide and ammonia, markers of H. pylori, a stomach bacterium linked to cancer. It is intended for the capsule.

IEEE Sensors Journal

2018 · QU

Graphene-based force sensing in grasper jaws

A film of reduced graphene oxide in PDMS, which can be cast to any shape, measured forces from 0.5 to 20 N on a grasper tip.

IEEE ICIRD

Most cited first

Papers, grants and patents

Most cited papers

All 13 papers in this area

Grants

  • 2015Neuromorphic Tactile Sensing: A Paradigm Shift for Prosthetics and Robotic Surgery
    US$823,782 · Qatar National Research Fund · Lead Principal Investigator
  • 2012Integrated Bio-Sensors and Automated Instrumentation for Early Stomach Cancer Detection Using Flexible Capsule Endoscope
    US$1,035,523 · Qatar National Research Fund · Co-Lead Principal Investigator
  • 2012Development of Smart Minimum Invasive Surgery Tools with Tactile Sensing Capabilities for Telerobot Surgery System
    US$1,018,554 · Qatar National Research Fund · Co-Lead Principal Investigator

Patent